S11 Series Three Phase Oil-Immersed Distribution Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument
Phase: Three
Still deciding? Get samples of US$ 3500/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
16.52 Million USD
Plant Area
35000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
  • S11 Series Three Phase Oil-Immersed Distribution Transformer
Find Similar Products
  • Overview
  • Product Description
  • Workshop Image
  • Company Profile
Overview

Basic Info.

Model NO.
S11
Cooling Method
Oil-immersed Type Transformer
Winding Type
Multi-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
High Frequency
Shape of Core
EI
Brand
Honle
Vector Group
Ydn0 or Dyn11
Rated Capacity
30~2500kVA
Transport Package
Wooden Case
Trademark
HONLE
Origin
Zhengjiang, China
HS Code
850440199
Production Capacity
2500 Pieces Per Year

Product Description

S11 Series Three Phase Oil-Immersed Distribution Transformer

 
Product Description

 

OVERVIEW

Iron core:
the iron core is made by crystal grain-oriented silicon-steel sheet; GEORG cross cut shear (made in West Germany) is adopted to cut the silicon-steel sheet with a 45°joint seam; fold the sheet into a multistage roll cross-section to reduce the noise and power consumption.

Coil:
cylinder type for high voltage; cylinder type or foil type for low voltage; this can increase the ability to resist short circuit and strike; and the distribution of magnetic path is more rational.

oil tank:
the oil tank is made by fine cold-rolled steel sheets; GEORG corrugation oil tank production-line is adopted; to meet environmental needs, then, antiseptic coating material is applied on the surface, which can meet the requirements for petroleum and chemical industry (much oil stain and many chemical substances). In addition, the corrugations not any possess heat radiation function, but also meet the requirement for oil expansion and oil contraction trader normal performance. The isolation from air guarantees a low aging speed of oil and a long life expectancy of transformer.

Insulation structure:
oil-immersed distribution transformer adopts A-level insulation structure; high voltage coil and low voltage coil are concentric; the space between coils is cardboard sleeve small oil clearance oil partition structure.

S11 Series Three Phase Oil-Immersed Distribution Transformer
Technical parameters
Rated
Capacity
Voltage
Combination
Vector
Group
No-load
Loss
Load
Loss
No-load
Current
Impedance
Voltage
Total
Weight
Exterior
Size
Installation center
/Installation hole
(kVA) High
voltage
Tap
range
Low voltage
(kV)
  (W) (W) (%) (%) (kg) (L*W*H)(mm) (mm)
30 6
6.3
10
10.5
11
±5%
or
±2*2.5%
0.4 Ydn0
or
Dyn11
100 630/600 1.8 4.0

 
335 1030*690*860 400*400/4*φ14
50 130 910/870 1.6 410 1045*700*925 400*400/4*φ14
63 150 1090/1040 1.5 460 1075*710*940 400*400/4*φ14
80 180 1310/1250 1.4 490 1080*715*995 400*400/4*φ19
100 200 1580/1500 1.3 550 1110*730*1020 400*400(550)/4*φ19
125 240 1890/1800 1.2 615 1135*740*1035 400*400(550)/4*φ19
160 280 2310/2200 1.1 695 1155*755*1050 550*550/4*φ19
200 340 2730/2600 1 790 1200*770*1075 550*550/4*φ19
250 400 3200/3050 0.9 930 1240*800*1100 550*550/4*φ19
315 480 3830/3650 0.8 1110 1305*840*1120 550*550/4*φ19
400 570 4520/4300 0.7 1290 1390*900*1160 660*660/4*φ19
500 680 5410/5150 0.7 1510 1500*990*1195 660*660/4*φ19
630 810 6200 0.6 4.5 1730 1580*1030*1305 660*660/4*φ19
800 980 7500 0.6 2075 1705*1140*1360 820*820/4*φ19
1000 1150 10300 0.5 2490 1730*1290*1395 820*820/4*φ19
1250 1360 12000 0.4 2960 1780*1320*1480 820*820/4*φ19
1600 1640 14500 0.4 3515 1890*1430*1520 820*820/4*φ19
2000 1940 18300 0.4 5 4880 2050*1360*1840 820*820/4*φ19
2500 2290 21200 0.4 6010 2170*1430*2015 1070*1070/4*φ19
Note: For transformers with rated capacity of 500 kVA and below, the load loss above the ramp in the table is applicable to the Dyn11 connection group, and the load loss below the ramp is applicable to the Yyn0 connection group.


S11 Series Three Phase Oil-Immersed Distribution Transformer
Workshop Image

 

Workshop Image


S11 Series Three Phase Oil-Immersed Distribution Transformer

 
Company Profile

 

Company Profile

S11 Series Three Phase Oil-Immersed Distribution Transformer
S11 Series Three Phase Oil-Immersed Distribution Transformer

S11 Series Three Phase Oil-Immersed Distribution Transformer
S11 Series Three Phase Oil-Immersed Distribution Transformer

S11 Series Three Phase Oil-Immersed Distribution Transformer

Last but not Least

Dear friends, we are your Reliable Partner!

We appreciate if you leave detailed requirements here or send emails to our mail box.

We will get back to you as soon as possible. Thanks very much.

It's our honor to have the opportunity to work with you.
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier