Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator

Product Details
Customization: Available
Application: High-voltage, Low-voltage, High-temperature
Material: Composite Polymer

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
16.52 Million USD
Plant Area
35000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
  • Hl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator
Find Similar Products

Basic Info.

Model NO.
HL5W
Structure
Post Insulator
Type
A Type Insulator
Usage
High Voltage Power Transmission, Insulation, Driving
Connection Method
Spherical Type
Size of Bearing Capacity
Oil Immerised
Certification
CCC, CE, ISO9001
Color
White
Brand
Honle
Ambient Air Temperature
-55ºC to +50ºC
Altitude
≤2000m
Transport Package
Standard
Specification
CE
Trademark
HONLE
Origin
Zhejiang, China
HS Code
8535400000
Production Capacity
50000PCS Per Month

Product Description

HL5W(HL10W)3KV-36KV With Insulating Bracket
Hl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorApplication     
Protection of medium/high voltage AC networks against both, multiple atmospheric and switching  over voltages  as well as Very Fast Transients (VFT). Suitable for the protection of transformers, transformers in arc furnace applications, cables,generators,parallel to capacitor banks,and railway vehicles.Can be used mechanically as support insulator or as suspension insulator in case  of  application as line arrester  For indoor and outdoor installation.

Usual service condition                                                                          
a) Ambient air temperature within the range of -55ºC to +50ºC.
b) Altitude not exceeding 2000m.
c) Frequency of the A.C. Power supply not less than 48Hz and not exceeding 62Hz.
d) Power frequency voltage applied continuously between the terminals of the arrester not exceeding its continuous operating voltage.
e) Maximum wind speed not exceeding 35m/s.
f) Earthquake intensity not exceeding 7 degrees.


Advantage                                                             
-Low residual voltage
-Long protection distance
-High energy input capacity
-Stable U-I characteristic even after multiple strokes
-Proof against ageing
-Explosion and shatter-resistant design
-Pollution resistant and UV-stable
-Housing resistant to rough handling
-Maintenance free
-Stable against shock and vibration
-High mechanical resistance
Technical Data of Metal Oxide Surge Arrester (Type: YH5W-21~36)
  Manufacturer     Honle Group Co.,Ltd
  Rated Voltage kV 21 24 27 30 33 36
  Nominal discharge current kA 5 5 5 5 5 5
1 General Feature Unit            
1.1 Applicable standard                          IEC60099-4(2004)
1.2 Type designation   YH5W-21 YH5W-24 YH5W-27 YH5W-30 YH5W-33 YH5W-36
1.3 Housing material   Silicone  rubber Silicone  rubber Silicone  rubber Silicone  rubber Silicone  rubber Silicone  rubber
1.4 With(out) gqps   Without Without Without Without Without Without
2 Ratings & characteristics              
2.1 Rated frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60
2.2 Residual voltage at              
    -lightning impule 8/20μs kV 59.5 68 76.5 85 93.5 102
    -steep current impulse 1/10μs kV 68.6 78.4 88.2 98 107.8 117.6
    -switching impulse 30/60μs(10kA&up) kV 51.2 58.5 65.8 73.1 80.4 87.7
    -switching wave(class 1&up) kA 0.5 0.5 0.5 0.5 0.5 0.5
2.3 Continuous operating voltage kV 17.9 20.4 23 25.5 28 30.6
2.4 Power freqncy reference voltage kV 21 24 27 30 33 36
2.5 Long duration current impulse withstand              
    -2ms rectangular current withstand A 150 150 150 150 150 150
2.6 Operating duty              
    -4/10μs high current impulse withstand kA 65 65 65 65 65 65
2.7 Housing insulation level      
    -lightning impulse kV 95 110 120 135 150 170
    -power frequency,wet 1 min kV 50 55 60 65 70 80
2.8 Partial discharge pC                                         10
2.9 Power frequency voltage versus time     1.15UR-0.1s   1.10UR-1s   1.05UR-1s   1UR-1200s
2.10 Other ratings & characteristics      
    -torsional Nm 60 60 60 60 60 60
2.11   creepage distance/rated voltage ratio(General) kV/mm ≥25 ≥25 ≥25 ≥25 ≥25 ≥25
OUR FACTORY
Hl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket InsulatorHl5w (HL10W) 3kv-36kv with Insulating Bracket Insulator