Oil-immersed distribution transformer adopts A-level insulation structure;high voltage coil and low voltage coil are concentric;the space between coils is cardboard sleeve small oil clearance oil partition structure.
Rated capacity |
Voltage combination |
Vector Group |
No-load loss |
Load-loss | No-load loss |
Impedance voltage |
Total Weight |
Exterior size |
Installation center/ Installation hole |
||
(kVA) | High (kv) |
Tap range |
Low (kv) |
(W) | (W) | (%) | (%) | (kg) | (L*W*H)(mm) | (mm) | |
30 | 6 6.3 10 10.5 11 |
±5% or ±2*2.5% |
0.4 |
Ydn0 or Dyn11 |
100 | 630/600 | 1.8 | 4.0 |
335 | 1030*690*860 | 400*400/4*φ14 |
50 | 130 | 910/870 | 1.6 | 410 | 1045*700*925 | 400*400/4*φ14 | |||||
63 | 150 | 1090/1040 | 1.5 | 460 | 1075*710*940 | 400*400/4*φ14 | |||||
80 | 180 | 1310/1250 | 1.4 | 490 | 1080*715*995 | 400*400/4*φ19 | |||||
100 | 200 | 1580/1500 | 1.3 | 550 | 1110*730*1020 | 400*400(550)/4*φ19 | |||||
125 | 240 | 1890/1800 | 1.2 | 615 | 1135*740*1035 | 400*400(550)/4*φ19 | |||||
160 | 280 | 2310/2200 | 1.1 | 695 | 1155*755*1050 | 550*550/4*φ19 | |||||
200 | 340 | 2730/2600 | 1 | 790 | 1200*770*1075 | 550*550/4*φ19 | |||||
250 | 400 | 3200/3050 | 0.9 | 930 | 1240*800*1100 | 550*550/4*φ19 | |||||
315 | 480 | 3830/3650 | 0.8 | 1110 | 1305*840*1120 | 550*550/4*φ19 | |||||
400 | 570 | 4520/4300 | 0.7 | 1290 | 1390*900*1160 | 660*660/4*φ19 | |||||
500 | 680 | 5410/5150 | 0.7 | 1510 | 1500*990*1195 | 660*660/4*φ19 | |||||
630 | 810 | 6200 | 0.6 | 4.5 |
1730 | 1580*1030*1305 | 660*660/4*φ19 | ||||
800 | 980 | 7500 | 0.6 | 2075 | 1705*1140*1360 | 820*820/4*φ19 | |||||
1000 | 1150 | 10300 | 0.5 | 2490 | 1730*1290*1395 | 820*820/4*φ19 | |||||
1250 | 1360 | 12000 | 0.4 | 2960 | 1780*1320*1480 | 820*820/4*φ19 | |||||
1600 | 1640 | 14500 | 0.4 | 3515 | 1890*1430*1520 | 820*820/4*φ19 | |||||
2000 | 1940 | 18300 | 0.4 | 5 | 4880 | 2050*1360*1840 | 820*820/4*φ19 | ||||
2500 | 2290 | 21200 | 0.4 | 6010 | 2170*1430*2015 | 1070*1070/4*φ19 |