Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Still deciding? Get samples of US$ 1200/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
16.52 Million USD
Plant Area
35000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate
  • Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
  • Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
  • Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
  • Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
Find Similar Products

Basic Info.

Model NO.
HLZX
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Poles Number
3
Function
Conventional Circuit Breaker
Transport Package
Standard Export Package
Specification
15.5KV-38KV, 630A, 800A
Trademark
Honle
Origin
Zhejiang, China
Production Capacity
5000PCS/Month

Product Description

Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
 
Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser
Recloser principle
 
Reclosers are used in overhead lines and in substations.Like circuit-breakers they are capable of switching normal and
fault currents. They are equipped with sensors and controller being the protection and control device. In case of a temporary line fault, they can trip and reclose up to four times, thus
avoiding longer network interruptions.
 
Recloser cycle
In case of a network fault, the recloser opens and recloses several times. In case of temporary faults, the automatic reclosing significantly reduces the outage times. While the trip settings for each operation can be set individually.
 
Design of switch unit
Each vacuum interrupter is embedded in a solid-insulated pole made of weather-proof cycloaliphatic epoxy-resin. The vacuum interrupter is vertically mounted inside the pole, providing a long service life. Each pole is equipped with an integrated current transformer and a resistive voltage sensor.
 
Operating mechanism
The recloser is operated by a magnetic actuator,the actuator is a bi-stable system, locked in the end positions by permanent magnets.If not in operation, the magnet coils do not consume any power. The operating mechanism housing is made of stainless steel for outdoor applications. it also accommodates the position indicator and a mechanical operations counter.
Mechanical lockout
The recloser can be tripped manually. If the handle is pulled, the recloser opens and is simultaneously locked out electrically and mechanically. The handle stays extended, thus indicating the interlocked state. To close the recloser again, the handle must first be pushed back to the operation position in order to release the lockout.Then the recloser can be closed electrically via the controller.
 
Rated continuous current
(A)
Rated duration of short-circuit
(S)
Rated short-circuit breaking current
(KA)
Rated short-circuit making current
(KA)
Rated lightning impulse withstand voltage
(KV)
Rated short-duration P.F. withstand voltage
(KV)
Impedance μΩ between connections
(μΩ)
Creepage distance, phase-to-earth
(mm)
Clearance, phase-to-phase
(mm)
Minimum clearance, phase-to-earth
(mm)
Weight
(KG)
Line charging current
(A)
Cable charging current
(A)
Max. interrupting time / max. closing time
(ms)
15.5kV 50/60Hz
630 3 12.5 31.5 110 50 60 850 320 270 130 2 10 40/60
800 3 12.5 31.5 110 50 60 850 320 270 130 2 10 40/60
630 3 16 40 110 50 60 850 320 270 130 2 10 40/60
800 3 16 40 110 50 60 850 320 270 130 2 10 40/60
27KV 50/60Hz
630 3 12.5 31.5 125 60 60 850 320 270 140 5 25 40/60
800 3 12.5 31.5 125 60 60 850 320 270 140 5 25 40/60
630 3 16 40 125 60 60 850 320 270 140 5 25 40/60
800 3 16 40 125 60 60 850 320 270 140 5 25 40/60
630 3 16 40 170 70 60 1290 320 350 150 5 25 40/60
800 3 16 40 170 70 60 1290 320 350 150 5 25 40/60
38KV 50/60Hz
630 3 12.5 31.5 170 70 60 1290 320 350 150 5 40 40/60
800 3 12.5 31.5 170 70 60 1290 320 350 150 5 40 40/60
630 3 16 40 170 70 60 1290 320 350 150 5 40 40/60
800 3 16 40 170 70 60 1290 320 350 150 5 40 40/60

Honle Pole Mounted Outdoor Vacuum Auto Circuit Switch with Controller Recloser

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier