Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use

Product Details
Customization: Available
Breaking Capacity: High Voltage Circuit Breakers
Operation: Energy-storage Type
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Diamond Member Since 2014

Suppliers with verified business licenses

Audited Supplier Audited Supplier

Audited by an independent third-party inspection agency

Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 30 foreign trading staff(s) and 17 staff(s) with over 6 years of overseas trading experience
Overseas Agent/Branch
The supplier has overseas agent/branch(s)
Management Certification
The supplier has quality management system certification, including:
ISO9001:2015 certificate
ISO45001:2018 certificate
ISO14001
to see all verified strength labels (27)
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
  • Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use
Find Similar Products

Basic Info.

Model NO.
HL
Speed
Normal Type Circuit Breaker
Arc-extinguishing Medium
Vacuum
Installation
Fixed
Structure
Auto Recloser
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker, Circuit-Breaker Failure Protection, Overcurrent Protection, Multiple Opening/Closing
Certification
CE, CCC, IEEE C37.60
Rated Continuous Current
630/800A
Rated Duration of Short-Circuit
3s
Frequency
50/60 Hz
Rated Short-Circuit Breaking Current
12.5/16ka
Rated Short-Circuit Making Current
31.5/40ka
Rated Lightning Impulse Withstand Voltag
125/170kv
Rated Short-Duration P.F. Withstand Volt
60/70kv
Line Charging Current
2/5A
Cable Charging Current
10/25/40A
Max. Interrupting Time / Max.Closing Tim
10/60ms
Transport Package
Standard Export Package
Specification
15.5KV-38KV, 630A, 800A
Trademark
Honle
Origin
Zhejiang, China
HS Code
8535210000
Production Capacity
5000PCS/Month

Packaging & Delivery

Package Size
97.00cm * 46.00cm * 85.00cm
Package Gross Weight
140.000kg

Product Description

  
Recloser cycle
In case of a network fault, the recloser opens and recloses several times. In case of temporary faults, the automatic reclosing significantly reduces the outage times. While the trip settings for each operation can be set individually.
 
Design of switch unit
Each vacuum interrupter is embedded in a solid-insulated pole made of weather-proof cycloaliphatic epoxy-resin. The vacuum interrupter is vertically mounted inside the pole, providing a long service life. Each pole is equipped with an integrated current transformer and a resistive voltage sensor.
 
Operating mechanism
The recloser is operated by a magnetic actuator,the actuator is a bi-stable system, locked in the end positions by permanent magnets.If not in operation, the magnet coils do not consume any power. The operating mechanism housing is made of stainless steel for outdoor applications. it also accommodates the position indicator and a mechanical operations counter.
 
Mechanical lockout
The recloser can be tripped manually. If the handle is pulled, the recloser opens and is simultaneously locked out electrically and mechanically. The handle stays extended, thus indicating the interlocked state. To close the recloser again, the handle must first be pushed back to the operation position in order to release the lockout.Then the recloser can be closed electrically via the controller.
 
  Rated continuous current(A) Rated duration of short-circuit(s) Rated short-circuit breaking
currentkA)
Rated short-circuit making current(kA) Rated lightning impulse withstand voltage ((kV) Rated short-duration P.F. withstand voltage(kV) Impedance Ωμ between connections
(Ωμ)
Creepage distance, phase-to-earth(mm) Clearance, phase-to-phase(mm) Minimum clearance,
phase-to-earth(mm)
Weight
(kg)
Line
charging current(A)
Cable charging current(A) Max. interrupting
time / max.closing time(ms)
15.5kV  50/60Hz
HL15-630-12-N 630 3 12.5 31.5 110 50 60 850 320 270 130 2 10 40/60
HL15-800-12-N 800 3 12.5 31.5 110 50 60 850 320 270 130 2 10 40/60
HL15-630-16-N 630 3 16 40 110 50 60 850 320 270 130 2 10 40/60
HL15-800-16-N 800 3 16 40 110 50 60 850 320 270 130 2 10 40/60
27kV  50/60Hz
HL27-630-12-N 630 3 12.5 31.5 125 60 60 850 320 270 140 5 25 40/60
HL27-800-12-N 800 3 12.5 31.5 125 60 60 850 320 270 140 5 25 40/60
HL27-630-16-N 630 3 16 40 125 60 60 850 320 270 140 5 25 40/60
HL27-800-16-N 800 3 16 40 125 60 60 850 320 270 140 5 25 40/60
HL27-630-16-H 630 3 16 40 170 70 60 1290 320 350 150 5 25 40/60
HL27-800-16-H 800 3 16 40 170 70 60 1290 320 350 150 5 25 40/60
38kV  50/60Hz
HL38-630-12-N 630 3 12.5 31.5 170 70 60 1290 320 350 150 5 40 40/60
HL38-800-12-N 800 3 12.5 31.5 170 70 60 1290 320 350 150 5 40 40/60
HL38-630-16-N 630 3 16 40 170 70 60 1290 320 350 150 5 40 40/60
HL38-800-16-N 800 3 16 40 170 70 60 1290 320 350 150 5 40 40/60

Honle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser UseHonle Pole Mounted Outdoor Automatic Circuit Recloser for Outdoor Substation Auto Recloser Use

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier