Customization: | Available |
---|---|
Certification: | VDE, CCC, ISO9001 |
Shell Material: | Metal-Clad |
Still deciding? Get samples of $ !
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
·Low-carbon and environmentally-friendly
·Strong weather resistance, and a wide range of application
·Less maintenance
·Good insulation performance,safe and reliable operation
·Intelligentialize
Cabinet size(WxDxH) | Circuit breaker cabinet | Cable connection cabinet | PT cabinet |
Top expansion | 420×850×1950 | 420×850×1950 | 600×850×1950 |
Side expansion | 420×850×2000 | 420×850×2000 | 600×850×1950 |
The main technical parameters of the Environmental Gas Insulated RMU
Rated yoltage | kV | 12 |
Rated current | A | 630 |
Arc extinguishing method | Vacuum switch tube | |
Insulation method | Pure air or nitrogen | |
Rated short circuit breaking current | kV | 20 |
Rated short circuit breaking times | Times | 30 |
Rated short-circuit closing current (peak) |
KV | 50 |
Rated short-time withstand current 3s (rms) | kA | 20(Main circuit),17,4(Earthing circuit) |
Rated peak withstand current | kA | 50(Main circuit),43,5(Earthing circuit) |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage | kv | 75(Phase to earth,phase to phase),85(breaking) |
partial discharge | PC | ≤20 |
Rated sequence of operations of vcbs | 0-0.3S-CO-180S-CO | |
Withstands internal arc faults | KA\S | 20/0.5 |
Mechanical life | Times | 10000(VCB) 3000(Isolating switch,Earthing switch) |
Main circuit resistance of each phase | μ 2 | 120 |
Earthing switch rated short-circuit making current (peak value) |
KA | 43,5 |
Earthing switch closing times | Times | 2 |
Degree of protection | MPa | IP67(Gas box),IP4X(body case) |
Rated gas pressure (gauge pressure) | MPa | 0.02 |
Minimum operating gas pressure | 0/0 | 0 |
Rated annual leakage rate | ppm | 0.01 |
Moisture content in air box | KV | ≤150 |
Auxiliary circuit power frequency withstand voltage(1min) |
2 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-circuit breaking current | kA | 20 |
Rated short-circuit closing current (peak) | kA | 50 |
Rated short-time withstand current 3s (rms) | kA | 20 |
Rated peak withstand current | kA | 50 |
Rated sequence of operations | 0.-0.3s-C.0.-180s-C.0 | |
Power frequency withstand voltage(1min) | kv | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage (peak) | kV | 75(Phase to earth,phase to phase),85(breaking) |
Partial discharge | PC | ≤5 |
Mechanical life | Times | 10000 |
Main loop resistance per phase | μQ | ≤110 |
Contact spacing | mm | 9±1 |
Contact pressure over-travel | mm | 3±0,5 |
Contact final pressure | N | 1800±100N |
Three-phase opening(different phases) | ms | ≤1 |
Contact closure bounce time | ms | ≤2 |
Closing time | ms | ≤70 |
Opening time | ms | ≤60 |
Average opening speed | m/s | 1.1±0.2 |
Average closing speed | m/s | 0.8±0.2 |
Rated number of short-circuit current breaks | Times | 30 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-time current 35(rms) | kA | 20 |
Rated peak withstand current | kA | 50 |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage (peak) | kv | 75(Phase to earth,phase to phase),85(breaking) |
Three-phase opening (different phases) | m m | ≤2 |
Mechanical life | Times | 3000 |
Total resistance of each phase main circuit | μQ | ≤60 |
Contact pressure | N | 160+20 |
Closing force | Nm | ≤100 |
Moving and static contact distance | mm | ≥125 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-time withstand current 2s(rms) | kA | 17,4 |
Rated peak withstand current | kA | 43.5 |
Power frequency withstand voltage(1min) | kv | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage (peak) | kV | 75(Phase to earth,phase to phase),85(breaking) |
Three-phase opening (different phases) | m m | ≤1 |
Mechanical life | Times | 3000 |
Total resistance of each phase main circuit | μQ | ≤60 |
Contact pressure | N | 160+20 |
Closing force | nm | ≤100 |
Rated short-circuit closing current | KA | 43,5 |
Closing times | Times | 2 |
Moving and static contact distance | mm | ≥125 |
Auxiliary circuit rated voltage | V | DC48,DC110,AC220,DC220 |
Auxiliary circuit power frequency withstand voltage (1min) | kv | 2 |
Opening and closing coil voltage | V | DC48,DC110,AC220,DC220 |
Opening coil current | A | 2 |
Closing coil current | A | 2 |
Rated voltage energy storage time | s | ≤20 |
Auxiliary switch rated voltage | V | DC48,DC110,AC220,DC220 |
Auxiliary switch rated current | A | 10 |
Pairs of the auxiliary switch contact | 808C |
Why choose us?
Shipping & Packing
Shipping Details: Standard Export carton
Shipping Details: 7-30 day after receing the deposit
Company Information
HONLE Electric Co.Ltd. is the manufacturer which specializes in developing, producing and marketing
industrial electrical products. It has three factories, the first one produces power supply, the second
one produces power transformer, and the third one produces complete set of equipment. As a member
of China Power Supply Society, since HONLE is founded, the company has been insisting on the theoretic
guideline of "science &technology is the first productive force" and holding up brand strategy as the
guideline, relying on forwarding power supply technology, perfecting craft and unwearied pursuing to quality.
We can show top quality and set up positive image of enterprisein domestic and foreign market.
Our Service
1.Your inquiry related to our product & price will be replied within 48 hours
2.Well-trained & experienced staff are to answer all your inquiries in English
3.Working time: 8:00am ~17:30pm, Monday to Saturday. (UTC+8)
4.Customized solution & perfect after-sale service
5. Payment: we can accept T/T, L/C, Western Union.
6. For large order, engineer can be sent to your country .