• Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
  • Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
  • Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
  • Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
  • Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
  • Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear

Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear

Certification: VDE, CCC, ISO9001
Shell Material: Stainless Steel
Voltage Level: High Voltage
Installation: Removable
Structure: Cabinet
Current: AC
Samples:
US$ 349/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
Kyn28A-12
Delivery
25-35days
Transport Package
Export Standard Packing
Specification
A GRADE
Trademark
HONLE
Origin
Zhejiang, China(Mainland)
HS Code
8504401990
Production Capacity
200PCS/Month

Product Description

Honle Kyn28A-12 Metal-Clad and Metal-Enclosed Switchgear

Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear

General
KYN28A-12(GZS1-12Z) mid-set type metal-clad and metal-enclosed switchgear (hereinafter referred to as switchgear) is a
new type product designed and developed by our company with domestic and international advanced technologies, it is an
ideal upgrading product for replacing the old metal-enclosed switchgear such as KYN1-10, JYN2-10, GBC-10 and so on. Its
advantages as follows: 

 The cabinet shell is made of al-zinc-coated steel sheet, through CNC processing and multiple bending technique, then    assembled with bolts. It is featured with high mechanical strength, neat and elegant appearance, powder coating treated
door, good shock and corrosion resistance. Ingress protection level of the shell reaches IP4X. 

 Main switch of switchgear can be configured with VD4 vacuum circuit breaker and C3 series fixed type load switch from ABB corporation, also can be configured with many homemade vacuum circuit breakers (such as VS1, VH1, VK, ZN28) instead of overseas similar products. 

 No matter which circuit breaker selected, make sure that the air insulation distance of its bare conductor is larger than
125mm, and compound insulation is larger than 60mm. The breakers are featured with long service life, high parameters,
less maintenance, small size, etc. 

This switchgear is applicable for three-phase power grid of AC 50Hz and class 3.6~12kV, used for electric energy receiving
and distribution, it controls, protects and monitors the circuits, can be used in single bus and single-bus segment system or
dual-bus systems. This switchgear complies with IEC298 Alternating-current metal-enclosed switchgear and controlgear for
rated voltage above 1kV and up to and including 52kV , IEC694 Common specifications for high-voltage switchgear and controlgear, GB3906 Alternating-current metal-enclosed switchgear for rated voltage of 3~36kV, DL404 Indoor AC high voltage switchgear panel, DIN.VDE0670 Alternating-current switchgear for rated voltage above 1kV, etc. It enjoys perfect and reliable anti-misoperation function.


Ambient conditions

1.  Ambient temperature: upper limit +40; lower limit: -15
2.  Altitude: no more than 4000m
3.  Relative humidity: daily average humidity no more than 95%, and monthly average no more than 90%
4.  Steam pressure: daily average pressure no greater than 2.2×10³MPa, monthly average no greater than 90%
5.  Seismic intensity: no greater than 8 degree
6.  No fire, explosive danger, grave filth, chemical corrosion and drastic vibration on the site.

 Advantages

1.  This switchgear is case metal-enclosed structure. In accordance with the national standard GB3906 and international standardIEC298, protection degreeIP2X. The metal-enclosed structure effectively prevents short-circuit failure by intruders.

2.  When air insulation distance between polar to polar or polar to ground ≤125mm, porcelain support insulators (≥8000N) is applied. All these ensure higher insulation intensity and stability.

3.  Breakers, both upper and lower insulation switches, grounding switches and interlock mechanisms between doors all takes force mechanical lock mode to meet the requirement of "five- prevention".

 

Switchgear Structure 
Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear

Specification 
ITEM UNIT DATA
Rated voltage KV 3.6,7.2,12
Rated frequency  Hz 50
Rated current of circuit breaker A 630,1250,1600,2000,2500,3150,4000 
Rated current of switchgear A 630,1250,1600,2000,2500,3150,4000 
Rated peak withstand current (4s) KA  16,20,25,31.5,40,50,63 
Rated peak withstand current (peak) KA  40,50,63,80,100,125,160 
Rated short-circuit breaking current  KA  16,20,25,31.5,40,50,63 
Rated short-circuit making current (peak) KA   40,50,63,80,100,125,160

Company
Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage SwitchgearHonle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage SwitchgearHonle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage SwitchgearHonle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear
Honle Kyn28A-12 Metal-Clad and Metal-Enclosed High Voltage Switchgear

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Registered Capital
16.52 Million USD
Plant Area
35000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate