HLHB-12 Environmental Gas Insulated Ring Main Unit
Summary
HLHB-12 environmental gas insulated Ring Main Unit is a complete set of power distribution device of 12KV, three-phase AC 50Hz, single bus and single bus segment system.The product has the characteristics of simple structure,flexible operation, reliable interlocking, convenient installation and so on, and different users can provide satisfactory technical solutions for different applications. The adoption of sensing technology, automatic control technology and information technology, coupled with advanced technical performance and simple and flexible assembly scheme, can meet the changing needs of the market, and apply to the intelligent requirements of the power grid.Rated voltage | kV | 12 |
Rated current | A | 630 |
Arc extinguishing method | Vacuum switch tube | |
Insulation method | Pure air or nitrogen | |
Rated short circuit breaking current | kV | 20 |
Rated short circuit breaking times | Times | 30 |
Rated short-circuit closing current(peak) |
KV | 50 |
Rated short-time withstand current3s(rms) | kA | 20(Main circuit),17,4(Earthing circuit) |
Rated peak withstand current | kA | 50(Main circuit),43,5(Earthing circuit) |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage | kV | 75(Phase to earth,phase to phase),85(breaking) |
Partial discharge | PC | ≤20 |
Rated sequence of operations of vcbs | O-0.3S-CO-180S-CO | |
Withstands internal arc faults | KA\S | 20/0.5 |
Mechanical life | Times | 10000(VCB) 3000(Isolating switch,Earthing switch) |
Main circuit resistance of each phase | μΩ | 120 |
Earthing switch rated short-circuit making current(peak value) |
KA | 43,5 |
Earthing switch closing times | Times | 2 |
Degree of protection | MPa | IP67(Gas box),IP4X(body case) |
Rated gas pressure(gauge pressure) | MPa | 0.02 |
Minimum operating gas pressure | 0/0 | 0 |
Rated annual leakage rate | ppm | 0.01 |
Moisture content in air box | KV | ≤150 |
Auxiliary circuit power frequency withstand voltage(1min) |
2 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-circuit breaking current | kA | 20 |
Rated short-circuit closing current(peak) | kA | 50 |
Rated short-time withstand current3s(rms) | kA | 20 |
Rated peak withstand current | kA | 50 |
Rated sequence of operations | 0.-0.3s-C.0.-180s-C.0. | |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage(peak) | kV | 75(Phase to earth,phase to phase),85(breaking) |
Partial discharge | PC | ≤5 |
Mechanical life | Times | 10000 |
Main loop resistance per phase | μΩ | ≤110 |
Contact spacing | mm | 9±1 |
Contact pressure over-travel | mm | 3±0, 5 |
Contact final pressure | N | 1800±100N |
Three-phase opening(different phases) | ms | ≤1 |
Contact closure bounce time | ms | ≤2 |
Closing time | ms | ≤70 |
Opening time | ms | ≤60 |
Average opening speed | m/s | 1.1±0.2 |
Average closing speed | m/s | 0.8±0.2 |
Rated number of short-circuit current breaks | Times | 30 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-time current 3S(rms) | kA | 20 |
Rated peak withstand current | kA | 50 |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage(peak) | kV | 75(Phase to earth,phase to phase),85(breaking) |
Three-phase opening(different phases) | mm | ≤2 |
Mechanical life | Times | 3000 |
Total resistance of each phase main circuit | μΩ | ≤60 |
Contact pressure | N | 160+20 |
Closing force | Nm | ≤100 |
Moving and static contact distance | mm | ≥125 |
Rated voltage | kV | 12 |
Rated current | A | 630 |
Rated short-time withstand current 2s(rms) | kA | 17,4 |
Rated peak withstand current | kA | 43.5 |
Power frequency withstand voltage(1min) | kV | 42(Phase to earth,phase to phase),48(breaking) |
Lightning impulse withstand voltage(peak) | kV | 75(Phase to earth,phase to phase),85(breaking) |
Three-phase opening(different phases) | mm | ≤1 |
Mechanical life | Times | 3000 |
Total resistance of each phase main circuit | μΩ | ≤60 |
Contact pressure | N | 160+20 |
Closing force | nm | ≤100 |
Rated short-circuit closing current | KA | 43,5 |
Closing times | Times | 2 |
Moving and static contact distance | mm | ≥125 |
Auxiliary circuit rated voltage | V | DC48,DC110,AC220,DC220 |
Auxiliary circuit power frequency withstand voltage(1min) | kV | 2 |
Opening and closing coil voltage | V | DC48,DC110,AC220,DC220 |
Opening coil current | A | 2 |
Closing coil current Rated voltage energy storage time |
A S |
2 ≤20 |
Auxiliary switch rated voltage | V | DC48,DC110,AC220,DC220 |
Auxiliary switch rated current | A | 10 |
Pairs of the auxiliary switch contact | 80 8C |