Customization: | Available |
---|---|
Application: | Power, Electronic, Instrument |
Phase: | Three |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() |
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Designation | unit | Required values | Proposed values | |
Kind | - | cabin, airtight | Cabin, hermetic | |
Maker | - | to indicate | Ne xans | |
Facility | - | interior | Interior | |
Execution | Tropicalized | Tropicalized | ||
Standard | - | IEC 6071-6076-60296-60354 | IEC 60076 | |
Rated frequency | Hz | 50 | 50 | |
Nominal power | kVA | 400 | 400 | |
Number of phases in primary / secondary | 3/3 | 3/3 | ||
Insulation level assigned to the primary | V | 17,500 | 17,500 | |
Rated primary operational voltage | V | 15,000 | 15,000 | |
Number of socket | 5 | 5 | ||
MV voltage adjustment off | - | ±2x2.5% | ±2x2.5% | |
Secondary no-load voltage, adjuster in position 0 | V | 410 | 410 | |
short circuit voltage | % | 4 | 4 | |
Rated primary current | AT | to indicate | 15.4 | |
Rated secondary current | AT | to indicate | 563 | |
No-load current / rated current | % | 1.6 | 1.6 | |
Coupling | - | Dyna 11 | Dyn11 | |
No-load losses, max. | w | 930 | 930 | |
Losses due to maximum load at 75°C | w | 4600 | 4600 | |
Maximum oil temperature under load | °C | 55 | ||
permanent | 55 | |||
Maximum temperature of the windings in | °C | 60 | 60 | |
steady state | ||||
Ambient temperature, max | °C | 50 | 50 | |
Cooling | - | ONAN | ONAN | |
Internal protection | DGPT2 | DG PT2 | ||
Dielectric | - | PCB-free mineral oil | PCB-free mineral oil | |
Winding material | electrolytic copper | electrolytic copper | ||
Degree of hermeticity | - | Total filling | Total filling | |
Oil level indicator | Yes | Yes | ||
Corrosion protection | Meets Specification | Meets Specification | ||
Lightning impulse withstand voltage 1, 2/50ps | kV | 95 | 95 | |
(33kV rated) | ||||
Dielectric withstand voltage 50 Hz (1 min) (side | kV | 38 | 38 | |
33kV) | ||||
Max noise level | dB | 65 | 65 | |
Total transformer mass including oil | kg | to indicate | 1640 | |
mass of oil | kg | to indicate | 319 | |
Maximum dimensions: | mm x mm x | 1535x1060x1405 | ||
Height width depth | mm | |||
Nameplate | 01 | 1 | ||
Ground connection | 01 | 1 | ||
Claw hole transport | 2 | 2 | ||
FURTHER INFORMATION | ||||
Ohmic resistance between phases: | ||||
High tension | Ω | To be indicated | 8.7741(75ºC) | |
Low tension | Ω | To be indicated | 0.002013(75ºC) | |
PAINT | ||||
Color | To be indicated | RAL7033 | ||
The manufacturer |