PRODUCTION OVERVIEW
-YGLZ1 -125~3200A.
The load isolation switch is suitable for the changeover of two sets of low voltage electric circuit or the changeover of 2 sets of on-load devices or safety insulation.
-Mode of operation:
Direct operation: handle is installed on the switch.
Operation outside the board: handle is installed outside the door of power distributing board.
-Products with observation windows can be provided according to the demand to observe directly the on and off state of contact.
-The products have three poles, four poles, and (three poleston and off neural pole).
-Extended shaft is used for the operation outside the board.
-Two sets of auxiliary contacts can be assembled according to the demand.
-Mechanical property and electric property correspond to the mechanical property and electric property of YGL-125~3200A.
-A bridge can provided to connect the inlet or outlet terminal of the switch.
Note: The bridge connection is chosen, an explanation is needed to indicate the inlet or outlet is connected with it.
YGLZ1-125~630A Outline and installation dimensions
Dimension of Bottom Board |
Specification |
1 |
M |
Z |
W |
Q |
YGLZ1-125A |
55 |
6.5 |
95 |
216 |
244 |
YGLZ1-160A |
55 |
6.5 |
95 |
216 |
244 |
YGLZ1-200A |
55 |
6.5 |
116 |
216 |
244 |
YGLZ1-250A |
55 |
6.5 |
116 |
216 |
244 |
YGLZ1-31^400A |
60 |
8.5 |
180 |
280 |
311 |
YGLZ1-500630A |
60 |
8.5 |
180 |
280 |
311 |
YGLZ1-1000-1600A |
60 |
8.5 |
180 |
280 |
311 |
Connecting Terminal
Specification |
External Dimension and Installation Dimension |
A |
B |
C |
D |
D1 |
E |
J |
J1 |
J2 |
K |
L |
P |
R |
S |
T |
U |
∅X |
Y |
Y1 |
F |
YGLZ1-125A-160A/3 |
300 |
135 |
228 |
89 |
190 |
160 |
120 |
37 |
195 |
95 |
7 |
36 |
20 |
25 |
3.5 |
115 |
9 |
55.5 |
126.5 |
49 |
YGLZ1-125A-160A/4 |
330 |
135 |
228 |
104 |
190 |
160 |
150 |
37 |
225 |
95 |
7 |
36 |
20 |
25 |
3.5 |
115 |
9 |
55.5 |
127.5 |
49 |
YGLZ1-200A-250A/3 |
340 |
165 |
250 |
110 |
215 |
180 |
160 |
37 |
235 |
115 |
9 |
50 |
25 |
28 |
3.5 |
140 |
10.5 |
63 |
145 |
76 |
YGLZ1-200A-250A/4 |
390 |
165 |
250 |
135 |
218 |
180 |
210 |
37 |
285 |
115 |
9 |
50 |
25 |
28 |
3.5 |
140 |
10.5 |
63 |
147 |
76 |
YGLZ1-315A-400A/3 |
410 |
234 |
340 |
150 |
278 |
241 |
211 |
44.5 |
298 |
175 |
10 |
65 |
32 |
37 |
5 |
205 |
10.5 |
83 |
193 |
94 |
YGLZ1-315A-400A/4 |
470 |
234 |
340 |
180 |
278 |
241 |
270 |
44.5 |
358 |
175 |
10 |
65 |
32 |
37 |
5 |
205 |
10.5 |
83 |
193 |
94 |
YGLZ1-500A-630A/3 |
410 |
250 |
340 |
150 |
278 |
241 |
211 |
44.5 |
298 |
175 |
10 |
65 |
40 |
45 |
6 |
215 |
12.5 |
83.5 |
193.5 |
94 |
YGLZ1-500A-630A/4 |
470 |
250 |
340 |
180 |
278 |
241 |
270 |
44.5 |
358 |
175 |
10 |
65 |
40 |
45 |
6 |
215 |
12.5 |
83.5 |
193.5 |
94 |
YGLZ1-1000~3200A Outline and installation dimensions