• Lw3 12kv Sf6 Outdoor Circuit Breaker
  • Lw3 12kv Sf6 Outdoor Circuit Breaker
  • Lw3 12kv Sf6 Outdoor Circuit Breaker
  • Lw3 12kv Sf6 Outdoor Circuit Breaker
  • Lw3 12kv Sf6 Outdoor Circuit Breaker

Lw3 12kv Sf6 Outdoor Circuit Breaker

Breaking Capacity: High Voltage Circuit Breakers
Operation: Electric Type
Speed: Normal Type Circuit Breaker
Arc-extinguishing Medium: SF6
Installation: Fixed
Structure: Load Break Switch
Samples:
US$ 1200/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5

Basic Info.

Model NO.
LW3
Poles Number
3
Type
Circuit Breaker
Function
Conventional Circuit Breaker
Rated Voltage
12kv
Rated Frequency
50/60Hz
Rated Current
630A
Transport Package
Standard Export Package
Trademark
Honle
Origin
Zhejiang, China
Production Capacity
5000PCS/Month

Product Description

Lw3 12kv Sf6 Outdoor Circuit Breaker
Lw3 12kv Sf6 Outdoor Circuit Breaker
Lw3 12kv Sf6 Outdoor Circuit Breaker
 
Lw3 12kv Sf6 Outdoor Circuit Breaker
Description:

- Type LW3-12/630-20 column-mounted circuit breakers are suitable for use with a rated voltage of 12kV.
- Rated current 630A, 50/60Hz distribution network off.
- Turning off the load current and overload current in the power system can automatically separate the fault distribution circuit segments.
- Switches with the latest technology of electronic controller, manual operation, electric operation and remote operation.
- The electronic controller is housed in a stainless steel case and can be used in all weather conditions.
- In addition, the box can also be installed with wired and wireless modems, which can achieve remote monitoring and control.
- Simple column installation and arrangement is convenient and fast, reducing the construction cost.

 

Rated parameters   Other technical parameters   Power frequency withstand voltage  
The rated voltage 12kV Internal arc test 20kA/0.1sec 10sec (wet test) 45kV
Rated current 630A Arc suppression medium SF6Gas 1min (dry test) 50kV
Rated frequency 50/60Hz Insulating medium SF6Gas 1min (dry test) 50kV
Short-time Tolerance Current (RMS) 20kA/4sec Creep distance (porcelain casing) 550mm
Creep distance (silicone sleeve) 615mm
Protection grade 54
 
Mechanical properties of <0.1sec Impact pressure (1.2×50μs)   gas pressure  
Closing/opening time 10,000 times relatively 85kV rated working pressure(kgf/cm2G,at20ºC) 0.7
Mechanical stability operation -25(-40)~70ºC Between the fracture 95kV Explosion-proof device operating pressure(kgf/cm2G) 4~6
Ambient temperature       minimum operating pressure(kgf/cm2G) 0.05
        Gas leakage rate(cc/sec) 1.1×10-7

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2014

Suppliers with verified business licenses

Rating: 5.0/5
Registered Capital
16.52 Million USD
Plant Area
35000 square meters
Management System Certification
ISO9001:2015, ISO14001:2015, ISO45001:2018 certificate